Medical Equipments
Features
- Light weight, portable size, and user friendly system
- Two digital display for CH1, CH2
- Two Spectrum timing 6 & 12sec. for Acute and chronic pain condition
- Two separate indicators for improper placement of CH1, CH2
Specification:
Therapy Mode:
- 4 Pole - Interferential therapy
- 4 Pole - Multivector - IFT
- 2 Pole - Premodulated - IFT
- TENS MODE : 1-150Hz(Modulated)
- Medium Frequencies : 2KHz & 4KHz
- Base AMF : 1 to 150Hz
- Sweep Programme : 7 Programes
- Intensity Control : 0 - 100 MA continuously variable
- Intensity Balance Contoral : To equalise 2 Channel Currents
- Timer : (0-30) Minutes, adjustable upto 99 minutes and auto cutoff with beep sound
- Patient Safety : Output is 100% Isolated
- Safety Standards : IEC601-1
- Patient Safety : While the instrument is on, if intensity is not at a minimum level, the Patient Safety circuit will not allow to set the time and hence no output.
-
Different Type of Multivectors
- 2PL - Acute Condition
- 4PL - Acute Condition
- 4PL - Sub Acute condition
- 4PNL - Chronic condition
Features
- Power Supply - SMPS based (NO NEED OF STABILIZER )
- Light weight, Slanding portable size and user friendly system.
- Digital Display for CH1
- LED indicator for CH2
Specification:
Therapy Mode:
- 4 Pole - Interferential therapy
- 4 Pole - Multivector - IFT
- 2 Pole - Premodulated - IFT
- RUSSIAN Current
- TENS Mode
MEDIUM FREQUENCIES:
- 2KHz
- 4KHz
- 6KHz
- 8KHz
- 10KHz
TENS MODE :
(1 - 150Hz) Modulate with carrier Frequency.
BASE AMF :
1 TO 150Hz
SWEEP FREQUENCY :
0 TO 150Hz
SWEEP PROGRAMME :
- Linear - Acute condition
- Trapezoidal - Sub Acute condition
- Non - Linear - Chronic condition
- Intensity Control : 0 - 100 MA continuously variable
- Intensity Balance Control : To equalise 2 channel currents.
MULTIVECTORS:
- 45° Linear
- 90° Linear
- 90° Trapezoidal
- 90° Non - Linear
TIMER :
Timer : (0-30) Minutes, adjustable upto 99 minutes and auto cutoff with beep sound
PATIENT SAFETY :
Output is 100% isolated
- Safety Standards : IEC 601 � 1
- Paint Safety : While the instrument is "ON", if intensity is not at a minimum level, the Patient Safety circuit will not allow to set the time and hence "NO" output.
For Specification and Features please refer : SNO : (1)
- PHYSIOTRON - IFT - PLUS/MODEL, Except:
- 12sec. spectrum timing and Digital Display for CH2
Features
- Light weight, compact design & User friendly system
- Digital controlled circuitry
- Plastic moulded light weight transducer with water resistace.
- Combination therapy facility - Available
- Digital display indicates output power in W/cm²
- Indicator for Treatment ON & Treatment OVER
Specification:
- Frequency : 1MHz
- Therapy Modes : Continuous & Pulsed
- Output Power : 15W in continuous & 21W in pulsed mode
- Intensity : Maximum power = 3W/cm²
- Safety standards : IEC 601-1
- Classification : Class 1 type B.F
- Patient safety : Output is 100% isolated
- Treatment Time : (0-30) Minutes, adjustable upto 99 minutes and auto cutoff with beep sound
- Pulse Frequency : 100Hz
- Pulse ratio : 1:1, 1:2, 1:4, 1:8, 1:16
Features
- Power supply - SMPS Based
- Compact size, Light weight & portable Model
For Specification and Features please refer :
- S.N0 : (3) PHYSIOSOUND - UT - 1MHz MODEL
Features
- Frequency : 1MHz & 3MHz
- Frequency selector switch for 1MHz & 3MHz
- Separate Transducer for 1MHz & 3MHz
- For other specification and features please refer S.No : (3)
PHYSIOSOUND - UT - 1MHz Model
For Specification and Features please refer:
- S.No : (1) PHYSIOTRON - IFT PLUS - MODEL AND
- S.No : (3) PHYSIOSOUND - UT MODEL
Features
- Continuous and Intermittent mode
- For the Treatment of Pelvic, Cervical, Lumbar and Upper Dorsal regions
- Patient Safety Switch
- LED - Indicators for Forward (Hold), Reverse, Rest, Treatment over & Check/Remote
- Buzzer Indicator for the Treatment Over
- Digital Controlled Circuitry
- Separate Traction Force Selector for CERVICAL & LUMBAR
- The Machine works only when the traction safety switch is connected
Specification
- Traction Force :
- 4 to 50Kgs.
- 4to 100Kgs. (with doubler - Optional)
- Cervical - Tension : 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14(Kgs.)
- Lumbar - Tension : 15, 18, 21, 24, 27, 30, 33, 36, 40, 45, 50(Kgs.)
- Hold Time : 10, 20, 40, 60, 80(sec.) with indicator
- Rest Time : 1, 5, 10, 15, 20(sec.) with indicator
- Treatment Time : (0-30) Minutes, adjustable upto 99 minutes and auto cutoff with beep sound
- Treatment mode : Static and intermittent
TECHNICAL SPECIFICATION
- Main Supply : 220 V/50Hz AC
- Dimension : L330/B225/H160(mm)
- Weight : 12.5 Kgs.
Features:
- LED indicators for all modes
- Audio indicators for surged faradic and interrupted Galvanic
- Treatment Mode : Faradic/Surged faradic/Galvanic/Interrupted Galvanic
Specification
Faradic:
- Frequency : 50Hz
- Pulse width : 0.7 ms
Surged Faradic:
- Frequency : 50Hz
- Surge Duration : 1 Sec. - 6 Sec.(Continuously adjustable)
Interrupted Galvanic:
- Frequency : 1Hz
- Duration : 30 ms - 300 ms(Continuously adjutable)
- Operation Voltage : 200V - 240V/50Hz
- Dimension : L215/B 145/H85(mm)
- Weight : 1Kg.
For Specification and Features Please Refer : S.NO.(10)
- PHYSIOSTIM - DT MODEL
- Except : Output Digital Meter
Features:
- LED indicators for all modes
- Audio indicators for Surged faradic and Interrupted Galvanic
- Treatment Mode : Faradic/Surged faradic/Galvanic/Interrupted Galvanic
Specification
- Duration : 0.01ms, 0.03ms, 0.1ms, 0.3ms, 1ms, 3ms, 10ms, 30ms, 100ms, 300ms and 1000ms
- Meter : Digital meter
- Polarity : To change the output polarity from (+ve to -ve) and (-ve to +ve)
- Faradic :
- Frequency = 50Hz
- Pulse width = 0.7ms
- Surged Faradic :
- Frequency = 50Hz
- Surge Duration = 1sec. - 6sec.(continuously adjustable)
- Rest Duration = 1sec. - 6sec.(continuously adjustable)
- Interrupted Galvanic :
- Pulse Rate 3/1 = Three Pulses per second
- 1/1 = One pulse per second
- 1/3 = one pulse per three second
Features:
- Two channel
- Separate PULSE width, frequency, continuous and Pulsed mode for CH1 and CH2.
- LED indicators for continuous and pulsed mode for each channel
Specification
- Pulse frequency range : Variable 5Hz to 120Hz
- Duration range : Variable 50 μsec. to 800 μsec.
- Output mode : Continuous and Pulsed
- Timer : (0-30) Minutes, adjustable upto 99 minutes and auto cutoff with beep sound
- Patient Safety : While the machine is on, if CH1 or CH2 intensity is not at minimum level, the paintent safety circuit will not allow to set the time and hence no output
Features:
- This is similar to imported TENS and has a lot of unique feature i.e. light weight, Portable and compact size etc.
- 3 in One (TENS, GAL, FARADIC)
- 9 V single Battery Operation
- AC Adapter Provision Provided
- LED to indicate the Frequecy variation
- TENS, GAL and FARADIC can be operated in either plain (or) intermittent mode
- Seperate intensity control for CH1 and CH2
- PEN - Electrode Provided
Specification
- Therapy Mode = TENS, GAL, FARADIC
- Frequency : 2 to 100Hz
- Pulse width = 400μ sec.
- Waveshape : B - phase
For Specification and Features, please refer : S.No:(12)
- PHYSIO - POCKET - TENSSTIM - 2CH MODEL
Specification :
- POWER OUTPUT : 300W
- Operation Frequency : 27.12MHz
- Automatic Timer : 0 to 30 min (Turns off Power after Predetermined time)
- Intensity Control : 5 Steps Smooth Control
- Tuning Control : Smooth Control with Indication on
- Fan : For longer valve life builtin cooling fan is incorporated
Features
- Specially Designed
- Very useful for Hosiptals, Nursing Homes, Pvt.Clinics.
- Physiotherapy and Rehabilitation Centers for all routine treatments
- For longer valve life builtin cooling fan is incorporated
- Disc Electrodes available
- Automatic Timer = 0 to 30MIN.
- Remote switch available
- Mobile on smooth running castors
Specification :
- Operation frequency : 27.12MHz
- Intensity Control : 5 Steps Smooth Control
- Tuning Control : Smooth Control with Indication on
Features
- M - Type Filament
- On / Off - indicator
- Deluxe Model Thermostat
- Indicator for Thermostat
- Thermostat control : 0° - 100°C
- Safety Fuse - Provided